formula_8_98
codes.eurocode.fpr_en_1992_1_1_2023.chapter_8_ultimate_limit_states.formula_8_98
Formula 8.98 from FprEN 1992-1-1:2023: Chapter 8 - Ultimate Limit State.
Classes:
-
Form8Dot98DistanceToPointOfContraflexure–Class representing formula 8.98 for the calculation of the distance between the centre of the support
codes.eurocode.fpr_en_1992_1_1_2023.chapter_8_ultimate_limit_states.formula_8_98.Form8Dot98DistanceToPointOfContraflexure
Form8Dot98DistanceToPointOfContraflexure(a_p_x: MM, a_p_y: MM, d_v: MM)
Bases: Formula
Class representing formula 8.98 for the calculation of the distance between the centre of the support area and the point of contraflexure.
The standard writes this as an expression bounded from below by [\(d_v\)], which is implemented as the maximum of the two.
[\(a_p\)] Distance between the centre of the support area and the point of contraflexure in the considered load combination [\(mm\)].
FprEN 1992-1-1:2023 (E) art. 8.4.3(2) - Formula (8.98)
Parameters:
-
a_p_x(MM) –[\(a_{p,x}\)] Maximum distance from the centroid of the control perimeter (which may be simplified according to Figure 8.21a)) to the point on the x-axis where the bending moment [\(m_{Ed,x}\)] is zero. The distance may be calculated according to 8.4.3(3) or using a linear elastic (uncracked) model. The local coordinate system [\((x,y)\)] has its origin at the centre of the supporting area and coincides with the reinforcement directions (principal directions in case of layers which are not orthogonal). In large columns, wall ends and wall corners, the origin of the local coordinate system may be placed inside the supporting area at a distance [\(1,5 d_v\)] from the relevant column or wall face if it is more favourable [\(mm\)].
-
a_p_y(MM) –[\(a_{p,y}\)] Maximum distance from the centroid of the control perimeter (which may be simplified according to Figure 8.21a)) to the point on the y-axis where the bending moment [\(m_{Ed,y}\)] is zero. The distance may be calculated according to 8.4.3(3) or using a linear elastic (uncracked) model. The local coordinate system [\((x,y)\)] has its origin at the centre of the supporting area and coincides with the reinforcement directions (principal directions in case of layers which are not orthogonal). In large columns, wall ends and wall corners, the origin of the local coordinate system may be placed inside the supporting area at a distance [\(1,5 d_v\)] from the relevant column or wall face if it is more favourable [\(mm\)].
-
d_v(MM) –[\(d_v\)] Shear-resisting effective depth of the slab according to Formula (8.91) [\(mm\)].
Source code in blueprints/codes/eurocode/fpr_en_1992_1_1_2023/chapter_8_ultimate_limit_states/formula_8_98.py
23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 | |
codes.eurocode.fpr_en_1992_1_1_2023.chapter_8_ultimate_limit_states.formula_8_98.Form8Dot98DistanceToPointOfContraflexure.latex
latex(n: int = 3) -> LatexFormula
Returns LatexFormula object for formula 8.98.
Source code in blueprints/codes/eurocode/fpr_en_1992_1_1_2023/chapter_8_ultimate_limit_states/formula_8_98.py
74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 | |