Skip to content

formula_8_94

codes.eurocode.fpr_en_1992_1_1_2023.chapter_8_ultimate_limit_states.formula_8_94

Formula 8.94 from FprEN 1992-1-1:2023: Chapter 8 - Ultimate Limit State.

Classes:

codes.eurocode.fpr_en_1992_1_1_2023.chapter_8_ultimate_limit_states.formula_8_94.Form8Dot94PunchingShearStressResistance

Form8Dot94PunchingShearStressResistance(
    gamma_v: DIMENSIONLESS,
    k_pb: DIMENSIONLESS,
    rho_l: DIMENSIONLESS,
    f_ck: MPA,
    d_dg: MM,
    d_v: MM,
)

Bases: Formula

Class representing formula 8.94 for the calculation of the design punching shear stress resistance of slabs without shear reinforcement.

The standard writes this as an expression bounded from above, which is implemented as a minimum of the two.

[\(\tau_{Rd,c}\)] Design punching shear stress resistance of slabs without shear reinforcement [\(MPa\)].

FprEN 1992-1-1:2023 (E) art. 8.4.3(1) - Formula (8.94)

Parameters:

  • gamma_v (DIMENSIONLESS) –

    [\(\gamma_V\)] Partial factor for shear design according to Table 4.3 (NDP) or Tables A.1 (NDP) and A.2 (NDP) [\(-\)].

  • k_pb (DIMENSIONLESS) –

    [\(k_{pb}\)] Punching shear gradient enhancement coefficient according to Formula (8.96), see Form8Dot96PunchingShearGradientEnhancementCoefficient [\(-\)].

  • rho_l (DIMENSIONLESS) –

    [\(\rho_l\)] Longitudinal reinforcement ratio at the control perimeter according to Formula (8.95), see Form8Dot95LongitudinalReinforcementRatioPunchingShear [\(-\)].

  • f_ck (MPA) –

    [\(f_{ck}\)] Characteristic compressive strength of concrete [\(MPa\)].

  • d_dg (MM) –

    [\(d_{dg}\)] Size parameter describing the failure zone roughness, which depends on the concrete type and its aggregate properties. The standard gives it as [\(16 + D_{lower} \leq 40\)] for concrete with [\(f_{ck} \leq 60\)] MPa, and as [\(16 + D_{lower} \cdot \left(60/f_{ck}\right)^2 \leq 40\)] for concrete with [\(f_{ck} > 60\)] MPa, both in millimetres. [\(D_{lower}\)] is the smallest value of the upper sieve size [\(D\)] in an aggregate for the coarsest fraction of aggregates in the concrete permitted by the specification of concrete according to EN 206; where [\(D_{max}\)] is known it may replace [\(D_{lower}\)], see the NOTE 2 to 8.2.1(4) [\(mm\)].

  • d_v (MM) –

    [\(d_v\)] Shear-resisting effective depth of the slab according to Formula (8.91), see Form8Dot91ShearResistingEffectiveDepth [\(mm\)].

Source code in blueprints/codes/eurocode/fpr_en_1992_1_1_2023/chapter_8_ultimate_limit_states/formula_8_94.py
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
def __init__(
    self,
    gamma_v: DIMENSIONLESS,
    k_pb: DIMENSIONLESS,
    rho_l: DIMENSIONLESS,
    f_ck: MPA,
    d_dg: MM,
    d_v: MM,
) -> None:
    r"""[$\tau_{Rd,c}$] Design punching shear stress resistance of slabs without shear reinforcement [$MPa$].

    FprEN 1992-1-1:2023 (E) art. 8.4.3(1) - Formula (8.94)

    Parameters
    ----------
    gamma_v : DIMENSIONLESS
        [$\gamma_V$] Partial factor for shear design according to Table 4.3 (NDP) or Tables A.1 (NDP)
        and A.2 (NDP) [$-$].
    k_pb : DIMENSIONLESS
        [$k_{pb}$] Punching shear gradient enhancement coefficient according to Formula (8.96), see
        Form8Dot96PunchingShearGradientEnhancementCoefficient [$-$].
    rho_l : DIMENSIONLESS
        [$\rho_l$] Longitudinal reinforcement ratio at the control perimeter according to Formula (8.95),
        see Form8Dot95LongitudinalReinforcementRatioPunchingShear [$-$].
    f_ck : MPA
        [$f_{ck}$] Characteristic compressive strength of concrete [$MPa$].
    d_dg : MM
        [$d_{dg}$] Size parameter describing the failure zone roughness, which depends on the concrete type
        and its aggregate properties. The standard gives it as [$16 + D_{lower} \leq 40$] for concrete with
        [$f_{ck} \leq 60$] MPa, and as [$16 + D_{lower} \cdot \left(60/f_{ck}\right)^2 \leq 40$] for concrete
        with [$f_{ck} > 60$] MPa, both in millimetres. [$D_{lower}$] is the smallest value of the upper sieve
        size [$D$] in an aggregate for the coarsest fraction of aggregates in the concrete permitted by the
        specification of concrete according to EN 206; where [$D_{max}$] is known it may replace
        [$D_{lower}$], see the NOTE 2 to 8.2.1(4) [$mm$].
    d_v : MM
        [$d_v$] Shear-resisting effective depth of the slab according to Formula (8.91), see
        Form8Dot91ShearResistingEffectiveDepth [$mm$].
    """
    super().__init__()
    self.gamma_v = gamma_v
    self.k_pb = k_pb
    self.rho_l = rho_l
    self.f_ck = f_ck
    self.d_dg = d_dg
    self.d_v = d_v

codes.eurocode.fpr_en_1992_1_1_2023.chapter_8_ultimate_limit_states.formula_8_94.Form8Dot94PunchingShearStressResistance.latex

latex(n: int = 3) -> LatexFormula

Returns LatexFormula object for formula 8.94.

Source code in blueprints/codes/eurocode/fpr_en_1992_1_1_2023/chapter_8_ultimate_limit_states/formula_8_94.py
 86
 87
 88
 89
 90
 91
 92
 93
 94
 95
 96
 97
 98
 99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
def latex(self, n: int = 3) -> LatexFormula:
    """Returns LatexFormula object for formula 8.94."""
    _equation: str = (
        r"\min\left(\frac{0.6}{\gamma_V} \cdot k_{pb} \cdot \left(100 \cdot \rho_l \cdot f_{ck} \cdot "
        r"\frac{d_{dg}}{d_v}\right)^{\frac{1}{3}}, \frac{0.5}{\gamma_V} \cdot \sqrt{f_{ck}}\right)"
    )
    _numeric_equation: str = latex_replace_symbols(
        template=_equation,
        replacements={
            r"\gamma_V": f"{self.gamma_v:.{n}f}",
            r"k_{pb}": f"{self.k_pb:.{n}f}",
            r"\rho_l": f"{self.rho_l:.{n}f}",
            r"f_{ck}": f"{self.f_ck:.{n}f}",
            r"d_{dg}": f"{self.d_dg:.{n}f}",
            r"d_v": f"{self.d_v:.{n}f}",
        },
        unique_symbol_check=False,
    )
    _numeric_equation_with_units: str = latex_replace_symbols(
        template=_equation,
        replacements={
            r"\gamma_V": f"{self.gamma_v:.{n}f}",
            r"k_{pb}": f"{self.k_pb:.{n}f}",
            r"\rho_l": f"{self.rho_l:.{n}f}",
            r"f_{ck}": rf"{self.f_ck:.{n}f} \ MPa",
            r"d_{dg}": rf"{self.d_dg:.{n}f} \ mm",
            r"d_v": rf"{self.d_v:.{n}f} \ mm",
        },
        unique_symbol_check=False,
    )
    return LatexFormula(
        return_symbol=r"\tau_{Rd,c}",
        result=f"{self:.{n}f}",
        equation=_equation,
        numeric_equation=_numeric_equation,
        numeric_equation_with_units=_numeric_equation_with_units,
        comparison_operator_label="=",
        unit="MPa",
    )