formula_8_83
codes.eurocode.fpr_en_1992_1_1_2023.chapter_8_ultimate_limit_states.formula_8_83
Formula 8.83 from FprEN 1992-1-1:2023: Chapter 8 - Ultimate Limit State.
Classes:
-
Form8Dot83TorsionalStressResistanceLongitudinalReinforcement–Class representing formula 8.83 for the torsional capacity when governed by yielding of the longitudinal
codes.eurocode.fpr_en_1992_1_1_2023.chapter_8_ultimate_limit_states.formula_8_83.Form8Dot83TorsionalStressResistanceLongitudinalReinforcement
Form8Dot83TorsionalStressResistanceLongitudinalReinforcement(
sum_a_sl: MM2, f_yd: MPA, t_eff: MM, u_k: MM, theta: DEG
)
Bases: Formula
Class representing formula 8.83 for the torsional capacity when governed by yielding of the longitudinal reinforcement.
It is one of the three resistances that Formula (8.81) takes the minimum of, together with Formulas (8.82) and (8.84). It applies to a single cell, thin-walled section or a sub-section with constant effective wall thickness.
The standard prints the numerator as the single quantity [\(\Sigma A_{sl} f_{yd}\)], the yield force of the longitudinal reinforcement. This class takes the area and the stress separately, which mirrors Formula (8.82) and lets the unit representation expose a mismatch. The two are equal only when every bar counted carries the same [\(f_{yd}\)]; for mixed steel grades, pass the area that gives the correct yield force.
[\(\tau_{t,Rd,sl}\)] Torsional capacity when governed by yielding of the longitudinal reinforcement [\(MPa\)].
FprEN 1992-1-1:2023 (E) art. 8.3.4(2) - Formula (8.83)
Parameters:
-
sum_a_sl(MM2) –[\(\Sigma A_{sl}\)] Sum of the areas of the longitudinal reinforcement that may be included in the calculation of the torsional capacity. The amount of longitudinal reinforcement considered in Formula (8.83) should have a resultant tensile force that acts at the centroid of the equivalent thin-walled closed cross-section. The reinforcement should generally be distributed according to 12.3.3(9) [\(mm^2\)].
-
f_yd(MPA) –[\(f_{yd}\)] Design yield stress of the longitudinal reinforcement [\(A_{sl}\)] [\(MPa\)].
-
t_eff(MM) –[\(t_{eff}\)] Constant effective wall thickness of the single cell, thin-walled section or sub-section, refer to 8.3.4(1) and to the definition of [\(t_{eff,i}\)] in 8.3.2(2) [\(mm\)].
-
u_k(MM) –[\(u_k\)] Perimeter of the area [\(A_k\)] [\(mm\)].
-
theta(DEG) –[\(\theta\)] Angle of compression field with respect to the longitudinal axis. It sits in the denominator through [\(\cot\theta\)], so the result grows without bound as the angle approaches 90 degrees. Formula (8.85) keeps it well away from there, but needs [\(\cot\theta_{min}\)] of 8.2.3(4) and is therefore not enforced here [\(degrees\)].
Source code in blueprints/codes/eurocode/fpr_en_1992_1_1_2023/chapter_8_ultimate_limit_states/formula_8_83.py
28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 | |
codes.eurocode.fpr_en_1992_1_1_2023.chapter_8_ultimate_limit_states.formula_8_83.Form8Dot83TorsionalStressResistanceLongitudinalReinforcement.latex
latex(n: int = 3) -> LatexFormula
Returns LatexFormula object for formula 8.83.
Source code in blueprints/codes/eurocode/fpr_en_1992_1_1_2023/chapter_8_ultimate_limit_states/formula_8_83.py