Skip to content

formula_8_77

codes.eurocode.fpr_en_1992_1_1_2023.chapter_8_ultimate_limit_states.formula_8_77

Formula 8.77 from FprEN 1992-1-1:2023: Chapter 8 - Ultimate Limit State.

Classes:

codes.eurocode.fpr_en_1992_1_1_2023.chapter_8_ultimate_limit_states.formula_8_77.Form8Dot77ShearStressResistanceAtInterfaceWithoutYielding

Form8Dot77ShearStressResistanceAtInterfaceWithoutYielding(
    c_v2: DIMENSIONLESS,
    f_ck: MPA,
    gamma_c: DIMENSIONLESS,
    mu_v: DIMENSIONLESS,
    sigma_n: MPA,
    k_v: DIMENSIONLESS,
    rho_i: DIMENSIONLESS,
    f_yd: MPA,
    k_dowel: DIMENSIONLESS,
    f_cd: MPA,
)

Bases: Formula

Class representing formula 8.77 for the design shear stress resistance at an interface where yielding of the reinforcement crossing it is not ensured.

It applies where the required reinforcement crossing the interface cannot be assumed to yield because of insufficient anchorage, for example in structural toppings. Where yielding is ensured, Formula (8.76) applies according to 8.2.6(3) and (5).

The printed line carries an upper bound, so the result is the smaller of the expression and that bound. The "where" list defines [\(\mu_v\)] and [\(\sigma_n\)] as in 8.2.6(5), so the two rules that paragraph states for [\(\sigma_n\)] apply here as well: a compressive stress is not taken larger than [\(0.60 \cdot f_{cd}\)], and for a tensile stress the term [\(\mu_v \cdot \sigma_n\)] is taken as zero. Compression is positive.

As in Formula (8.76), the cap on [\(\sigma_n\)] cannot govern the result for any [\(\mu_v\)] of Table 8.2, where the smallest value is 0,5: with [\(\sigma_n\)] at its cap that term alone reaches [\(0.30 \cdot f_{cd}\)], which already exceeds the whole upper bound of [\(0.25 \cdot f_{cd}\)]. The cap is implemented because the standard states it.

The remaining rules of 8.2.6(7) act on the coefficients rather than on this expression, so they are applied by the caller when choosing the inputs: [\(k_{dowel} = 0\)] when an intersecting bar sits closer than [\(10\phi\)] to an edge in the direction of the acting shear force; [\(c_{v2} = \mu_v = k_v = 0\)] for interface reinforcement at 90 degrees with an embedment length of at least [\(8\phi\)] but anchored for a stress lower than [\(0.5 \cdot f_{yd}\)]; and [\(c_{v2}\)] increased by a factor 1,2 for horizontal shear transfer in slab members with cast-in-place structural toppings and rough or very rough interfaces.

Footnote a of Table 8.2 belongs to that same group: it sets [\(c_{v2} = 0\)] when the interface carries tensile stresses caused by an external axial force in perpendicular direction, which is the very condition that makes [\(\sigma_n\)] negative here. This class does not apply it, since [\(c_{v2}\)] is an input and overriding a supplied value would be silent; a caller passing a negative [\(\sigma_n\)] is expected to have read that footnote when picking the coefficient. Table 8.2 also prints no coefficients at all for a keyed interface, so this formula has no tabulated inputs for keyed joints.

No lower bound is applied to the result, because the standard prints none, even though a caller can drive the expression negative by combining a zero coefficient with the tension case.

[\(\tau_{Rdi}\)] Design shear stress resistance at the interface without ensured yielding [\(MPa\)].

FprEN 1992-1-1:2023 (E) art. 8.2.6(7) - Formula (8.77)

Parameters:

  • c_v2 (DIMENSIONLESS) –

    [\(c_{v2}\)] Factor which depends on the roughness of the interface, see Table 8.2 and art. 8.2.6(6). Note that the standard refers to Table 8.1 here, while Table 8.1 gives effectiveness factors for confinement and it is Table 8.2 that lists this coefficient under the heading of Formula (8.77) [\(-\)].

  • f_ck (MPA) –

    [\(f_{ck}\)] Lowest compressive strength of the concretes at the interface [\(MPa\)].

  • gamma_c (DIMENSIONLESS) –

    [\(\gamma_C\)] Partial factor for concrete [\(-\)].

  • mu_v (DIMENSIONLESS) –

    [\(\mu_v\)] Factor which depends on the roughness of the interface, see Table 8.2 and art. 8.2.6(6) [\(-\)].

  • sigma_n (MPA) –

    [\(\sigma_n\)] Compressive stress over the interface area [\(A_i\)] caused by the minimum external axial force across the interface that acts simultaneously with the shear force, as defined in art. 8.2.6(5). Compression is positive here: a positive value is capped at [\(0.60 \cdot f_{cd}\)], and a negative value is a tensile stress, for which the term [\(\mu_v \cdot \sigma_n\)] is taken as 0 [\(MPa\)].

  • k_v (DIMENSIONLESS) –

    [\(k_v\)] Factor which depends on the roughness of the interface, see Table 8.2 and art. 8.2.6(6) [\(-\)].

  • rho_i (DIMENSIONLESS) –

    [\(\rho_i\)] Ratio [\(A_{si} / A_i\)] of the bonded reinforcement crossing the interface, as defined in art. 8.2.6(5) [\(-\)].

  • f_yd (MPA) –

    [\(f_{yd}\)] Design value of the yield strength of the reinforcement crossing the interface [\(MPa\)].

  • k_dowel (DIMENSIONLESS) –

    [\(k_{dowel}\)] Factor for dowel action which depends on the roughness of the interface, see Table 8.2 and art. 8.2.6(6). It is to be taken as 0 when an intersecting reinforcing bar sits closer than [\(10\phi\)] to an edge in the direction of the acting shear force [\(-\)].

  • f_cd (MPA) –

    [\(f_{cd}\)] Design value of the compressive strength of concrete [\(MPa\)].

Source code in blueprints/codes/eurocode/fpr_en_1992_1_1_2023/chapter_8_ultimate_limit_states/formula_8_77.py
 50
 51
 52
 53
 54
 55
 56
 57
 58
 59
 60
 61
 62
 63
 64
 65
 66
 67
 68
 69
 70
 71
 72
 73
 74
 75
 76
 77
 78
 79
 80
 81
 82
 83
 84
 85
 86
 87
 88
 89
 90
 91
 92
 93
 94
 95
 96
 97
 98
 99
100
101
102
103
104
105
106
107
108
def __init__(
    self,
    c_v2: DIMENSIONLESS,
    f_ck: MPA,
    gamma_c: DIMENSIONLESS,
    mu_v: DIMENSIONLESS,
    sigma_n: MPA,
    k_v: DIMENSIONLESS,
    rho_i: DIMENSIONLESS,
    f_yd: MPA,
    k_dowel: DIMENSIONLESS,
    f_cd: MPA,
) -> None:
    r"""[$\tau_{Rdi}$] Design shear stress resistance at the interface without ensured yielding [$MPa$].

    FprEN 1992-1-1:2023 (E) art. 8.2.6(7) - Formula (8.77)

    Parameters
    ----------
    c_v2 : DIMENSIONLESS
        [$c_{v2}$] Factor which depends on the roughness of the interface, see Table 8.2 and art. 8.2.6(6).
        Note that the standard refers to Table 8.1 here, while Table 8.1 gives effectiveness factors for
        confinement and it is Table 8.2 that lists this coefficient under the heading of Formula (8.77) [$-$].
    f_ck : MPA
        [$f_{ck}$] Lowest compressive strength of the concretes at the interface [$MPa$].
    gamma_c : DIMENSIONLESS
        [$\gamma_C$] Partial factor for concrete [$-$].
    mu_v : DIMENSIONLESS
        [$\mu_v$] Factor which depends on the roughness of the interface, see Table 8.2 and art. 8.2.6(6) [$-$].
    sigma_n : MPA
        [$\sigma_n$] Compressive stress over the interface area [$A_i$] caused by the minimum external axial
        force across the interface that acts simultaneously with the shear force, as defined in art. 8.2.6(5).
        Compression is positive here: a positive value is capped at [$0.60 \cdot f_{cd}$], and a negative value
        is a tensile stress, for which the term [$\mu_v \cdot \sigma_n$] is taken as 0 [$MPa$].
    k_v : DIMENSIONLESS
        [$k_v$] Factor which depends on the roughness of the interface, see Table 8.2 and art. 8.2.6(6) [$-$].
    rho_i : DIMENSIONLESS
        [$\rho_i$] Ratio [$A_{si} / A_i$] of the bonded reinforcement crossing the interface, as defined in
        art. 8.2.6(5) [$-$].
    f_yd : MPA
        [$f_{yd}$] Design value of the yield strength of the reinforcement crossing the interface [$MPa$].
    k_dowel : DIMENSIONLESS
        [$k_{dowel}$] Factor for dowel action which depends on the roughness of the interface, see Table 8.2
        and art. 8.2.6(6). It is to be taken as 0 when an intersecting reinforcing bar sits closer than
        [$10\phi$] to an edge in the direction of the acting shear force [$-$].
    f_cd : MPA
        [$f_{cd}$] Design value of the compressive strength of concrete [$MPa$].
    """
    super().__init__()
    self.c_v2 = c_v2
    self.f_ck = f_ck
    self.gamma_c = gamma_c
    self.mu_v = mu_v
    self.sigma_n = sigma_n
    self.k_v = k_v
    self.rho_i = rho_i
    self.f_yd = f_yd
    self.k_dowel = k_dowel
    self.f_cd = f_cd

codes.eurocode.fpr_en_1992_1_1_2023.chapter_8_ultimate_limit_states.formula_8_77.Form8Dot77ShearStressResistanceAtInterfaceWithoutYielding.latex

latex(n: int = 3) -> LatexFormula

Returns LatexFormula object for formula 8.77.

Source code in blueprints/codes/eurocode/fpr_en_1992_1_1_2023/chapter_8_ultimate_limit_states/formula_8_77.py
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
def latex(self, n: int = 3) -> LatexFormula:
    """Returns LatexFormula object for formula 8.77."""
    _equation: str = (
        r"\min\left(c_{v2} \cdot \frac{\sqrt{f_{ck}}}{\gamma_C} + \mu_v \cdot "
        r"\min\left(\max\left(\sigma_n, 0\right), 0.60 \cdot f_{cd}\right) + "
        r"k_v \cdot \rho_i \cdot f_{yd} \cdot \mu_v + "
        r"k_{dowel} \cdot \rho_i \cdot \sqrt{f_{yd} \cdot f_{cd}}, 0.25 \cdot f_{cd}\right)"
    )
    _numeric_equation: str = latex_replace_symbols(
        template=_equation,
        replacements={
            r"c_{v2}": f"{self.c_v2:.{n}f}",
            r"f_{ck}": f"{self.f_ck:.{n}f}",
            r"\gamma_C": f"{self.gamma_c:.{n}f}",
            r"\mu_v": f"{self.mu_v:.{n}f}",
            r"\sigma_n": f"{self.sigma_n:.{n}f}",
            r"k_{dowel}": f"{self.k_dowel:.{n}f}",
            r"k_v": f"{self.k_v:.{n}f}",
            r"\rho_i": f"{self.rho_i:.{n}f}",
            r"f_{yd}": f"{self.f_yd:.{n}f}",
            r"f_{cd}": f"{self.f_cd:.{n}f}",
        },
        unique_symbol_check=False,
    )
    _numeric_equation_with_units: str = latex_replace_symbols(
        template=_equation,
        replacements={
            # The roughness coefficients, the partial factor and the reinforcement ratio are dimensionless.
            r"c_{v2}": f"{self.c_v2:.{n}f}",
            r"f_{ck}": rf"{self.f_ck:.{n}f} \ MPa",
            r"\gamma_C": f"{self.gamma_c:.{n}f}",
            r"\mu_v": f"{self.mu_v:.{n}f}",
            r"\sigma_n": rf"{self.sigma_n:.{n}f} \ MPa",
            r"k_{dowel}": f"{self.k_dowel:.{n}f}",
            r"k_v": f"{self.k_v:.{n}f}",
            r"\rho_i": f"{self.rho_i:.{n}f}",
            r"f_{yd}": rf"{self.f_yd:.{n}f} \ MPa",
            r"f_{cd}": rf"{self.f_cd:.{n}f} \ MPa",
        },
        unique_symbol_check=False,
    )
    return LatexFormula(
        return_symbol=r"\tau_{Rdi}",
        result=f"{self:.{n}f}",
        equation=_equation,
        numeric_equation=_numeric_equation,
        numeric_equation_with_units=_numeric_equation_with_units,
        comparison_operator_label="=",
        unit="MPa",
    )