Skip to content

formula_8_76

codes.eurocode.fpr_en_1992_1_1_2023.chapter_8_ultimate_limit_states.formula_8_76

Formula 8.76 from FprEN 1992-1-1:2023: Chapter 8 - Ultimate Limit State.

Classes:

codes.eurocode.fpr_en_1992_1_1_2023.chapter_8_ultimate_limit_states.formula_8_76.Form8Dot76ShearStressResistanceAtInterface

Form8Dot76ShearStressResistanceAtInterface(
    c_v1: DIMENSIONLESS,
    f_ck: MPA,
    gamma_c: DIMENSIONLESS,
    mu_v: DIMENSIONLESS,
    sigma_n: MPA,
    rho_i: DIMENSIONLESS,
    f_yd: MPA,
    alpha: DEG,
    f_cd: MPA,
)

Bases: Formula

Class representing formula 8.76 for the calculation of the design shear stress resistance at an interface.

It applies to situations without reinforcement across the interface, or where the required reinforcement across the interface is anchored for [\(\sigma_{sd} = f_{yd}\)]. In other cases Formula (8.77) applies according to 8.2.6(7).

The printed line carries an upper bound, so the result is the smaller of the expression and that bound. The two rules the standard states in prose for [\(\sigma_n\)] are applied as well: a compressive stress is not taken larger than [\(0.60 \cdot f_{cd}\)], and for a tensile stress the term [\(\mu_v \cdot \sigma_n\)] is taken as zero.

Note that the cap on [\(\sigma_n\)] can never govern the result as long as [\(\mu_v\)] comes from Table 8.2, where the smallest value is 0,5: with [\(\sigma_n\)] at its cap the term [\(\mu_v \cdot \sigma_n\)] is at least [\(0.30 \cdot f_{cd}\)], which already exhausts the first part of the upper bound, so the upper bound governs instead. The cap is implemented because the standard states it, not because it changes an answer.

Two things this class deliberately does not do. It does not apply footnote a of Table 8.2, which sets [\(c_{v1} = 0\)] when the interface carries tensile stresses caused by an external axial force in perpendicular direction; that footnote belongs to the table, depends on the roughness class, and is applied by passing tension_perpendicular_to_interface to Table8Dot2CoefficientsSurfaceRoughness. And it puts no lower bound of zero on the result, because the standard prints none, even though the expression can turn negative for [\(c_{v1} = 0\)] combined with an angle beyond 90 degrees.

The printed line is not dimensionally homogeneous: [\(\sqrt{f_{ck}}\)] carries [\(MPa^{0.5}\)] while the result is in [\(MPa\)], so [\(c_{v1}\)] absorbs the remaining [\(MPa^{0.5}\)]. Table 8.2 prints it as a bare number, so it is typed dimensionless here, and the representation with units shows the square root of a stress rather than a stress.

[\(\tau_{Rdi}\)] Design shear stress resistance at the interface [\(MPa\)].

FprEN 1992-1-1:2023 (E) art. 8.2.6(5) - Formula (8.76)

Parameters:

  • c_v1 (DIMENSIONLESS) –

    [\(c_{v1}\)] Factor which depends on the roughness of the interface, see Table 8.2 and art. 8.2.6(6). The formula assumes the contact surface to be clean and free of laitance, dust or other adhesion-reducing particles [\(-\)].

  • f_ck (MPA) –

    [\(f_{ck}\)] Lowest compressive strength of the concretes at the interface [\(MPa\)].

  • gamma_c (DIMENSIONLESS) –

    [\(\gamma_C\)] Partial factor for concrete [\(-\)].

  • mu_v (DIMENSIONLESS) –

    [\(\mu_v\)] Factor which depends on the roughness of the interface, see Table 8.2 and art. 8.2.6(6) [\(-\)].

  • sigma_n (MPA) –

    [\(\sigma_n\)] Compressive stress over the interface area [\(A_i\)] caused by the minimum external axial force across the interface that acts simultaneously with the shear force. Permanent stresses caused by confinement of surrounding structural parts may be taken into account. Compression is positive here: a positive value is capped at [\(0.60 \cdot f_{cd}\)] as the standard requires, and a negative value is a tensile stress, for which the standard takes the term [\(\mu_v \cdot \sigma_n\)] as 0 [\(MPa\)].

  • rho_i (DIMENSIONLESS) –

    [\(\rho_i\)] Ratio [\(A_{si} / A_i\)], where [\(A_{si}\)] is the cross-sectional area of bonded reinforcement crossing the interface and anchored for [\(\sigma_{sd} = f_{yd}\)], including ordinary shear reinforcement if any, with adequate anchorage according to 11.4 at both sides of the interface. Tensile forces across interfaces shall be carried by reinforcement placed additional to the interface reinforcement [\(A_{si}\)] [\(-\)].

  • f_yd (MPA) –

    [\(f_{yd}\)] Design value of the yield strength of the reinforcement crossing the interface [\(MPa\)].

  • alpha (DEG) –

    [\(\alpha\)] Angle of the reinforcement crossing the interface as defined in Figure 8.15b), limited to [\(35° \leq \alpha \leq 135°\)]. For very smooth surfaces the standard limits it further to [\(35° \leq \alpha \leq 90°\)]; that tighter bound is not enforced here, because the roughness of the interface is not an input to this formula [\(degrees\)].

  • f_cd (MPA) –

    [\(f_{cd}\)] Design value of the compressive strength of concrete [\(MPa\)].

Source code in blueprints/codes/eurocode/fpr_en_1992_1_1_2023/chapter_8_ultimate_limit_states/formula_8_76.py
 48
 49
 50
 51
 52
 53
 54
 55
 56
 57
 58
 59
 60
 61
 62
 63
 64
 65
 66
 67
 68
 69
 70
 71
 72
 73
 74
 75
 76
 77
 78
 79
 80
 81
 82
 83
 84
 85
 86
 87
 88
 89
 90
 91
 92
 93
 94
 95
 96
 97
 98
 99
100
101
102
103
104
105
106
107
108
109
def __init__(
    self,
    c_v1: DIMENSIONLESS,
    f_ck: MPA,
    gamma_c: DIMENSIONLESS,
    mu_v: DIMENSIONLESS,
    sigma_n: MPA,
    rho_i: DIMENSIONLESS,
    f_yd: MPA,
    alpha: DEG,
    f_cd: MPA,
) -> None:
    r"""[$\tau_{Rdi}$] Design shear stress resistance at the interface [$MPa$].

    FprEN 1992-1-1:2023 (E) art. 8.2.6(5) - Formula (8.76)

    Parameters
    ----------
    c_v1 : DIMENSIONLESS
        [$c_{v1}$] Factor which depends on the roughness of the interface, see Table 8.2 and art.
        8.2.6(6). The formula assumes the contact surface to be clean and free of laitance, dust or other
        adhesion-reducing particles [$-$].
    f_ck : MPA
        [$f_{ck}$] Lowest compressive strength of the concretes at the interface [$MPa$].
    gamma_c : DIMENSIONLESS
        [$\gamma_C$] Partial factor for concrete [$-$].
    mu_v : DIMENSIONLESS
        [$\mu_v$] Factor which depends on the roughness of the interface, see Table 8.2 and art.
        8.2.6(6) [$-$].
    sigma_n : MPA
        [$\sigma_n$] Compressive stress over the interface area [$A_i$] caused by the minimum external
        axial force across the interface that acts simultaneously with the shear force. Permanent stresses
        caused by confinement of surrounding structural parts may be taken into account. Compression is
        positive here: a positive value is capped at [$0.60 \cdot f_{cd}$] as the standard requires, and a
        negative value is a tensile stress, for which the standard takes the term
        [$\mu_v \cdot \sigma_n$] as 0 [$MPa$].
    rho_i : DIMENSIONLESS
        [$\rho_i$] Ratio [$A_{si} / A_i$], where [$A_{si}$] is the cross-sectional area of bonded
        reinforcement crossing the interface and anchored for [$\sigma_{sd} = f_{yd}$], including ordinary
        shear reinforcement if any, with adequate anchorage according to 11.4 at both sides of the
        interface. Tensile forces across interfaces shall be carried by reinforcement placed additional to
        the interface reinforcement [$A_{si}$] [$-$].
    f_yd : MPA
        [$f_{yd}$] Design value of the yield strength of the reinforcement crossing the interface [$MPa$].
    alpha : DEG
        [$\alpha$] Angle of the reinforcement crossing the interface as defined in Figure 8.15b), limited
        to [$35° \leq \alpha \leq 135°$]. For very smooth surfaces the standard limits it further to
        [$35° \leq \alpha \leq 90°$]; that tighter bound is not enforced here, because the roughness of
        the interface is not an input to this formula [$degrees$].
    f_cd : MPA
        [$f_{cd}$] Design value of the compressive strength of concrete [$MPa$].
    """
    super().__init__()
    self.c_v1 = c_v1
    self.f_ck = f_ck
    self.gamma_c = gamma_c
    self.mu_v = mu_v
    self.sigma_n = sigma_n
    self.rho_i = rho_i
    self.f_yd = f_yd
    self.alpha = alpha
    self.f_cd = f_cd

codes.eurocode.fpr_en_1992_1_1_2023.chapter_8_ultimate_limit_states.formula_8_76.Form8Dot76ShearStressResistanceAtInterface.latex

latex(n: int = 3) -> LatexFormula

Returns LatexFormula object for formula 8.76.

Source code in blueprints/codes/eurocode/fpr_en_1992_1_1_2023/chapter_8_ultimate_limit_states/formula_8_76.py
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
def latex(self, n: int = 3) -> LatexFormula:
    """Returns LatexFormula object for formula 8.76."""
    _equation: str = (
        r"\min\left(c_{v1} \cdot \frac{\sqrt{f_{ck}}}{\gamma_C} + \mu_v \cdot "
        r"\min\left(\max\left(\sigma_n, 0\right), 0.60 \cdot f_{cd}\right) + "
        r"\rho_i \cdot f_{yd} \cdot \left(\mu_v \cdot \sin\alpha + \cos\alpha\right), "
        r"0.30 \cdot f_{cd} + \rho_i \cdot f_{yd} \cdot \cos\alpha\right)"
    )
    _numeric_equation: str = latex_replace_symbols(
        template=_equation,
        replacements={
            r"c_{v1}": f"{self.c_v1:.{n}f}",
            r"f_{ck}": f"{self.f_ck:.{n}f}",
            r"\gamma_C": f"{self.gamma_c:.{n}f}",
            r"\mu_v": f"{self.mu_v:.{n}f}",
            r"\sigma_n": f"{self.sigma_n:.{n}f}",
            r"f_{cd}": f"{self.f_cd:.{n}f}",
            r"\rho_i": f"{self.rho_i:.{n}f}",
            r"f_{yd}": f"{self.f_yd:.{n}f}",
            r"\alpha": f"{self.alpha:.{n}f}",
        },
        unique_symbol_check=False,
    )
    _numeric_equation_with_units: str = latex_replace_symbols(
        template=_equation,
        replacements={
            # The factors, the partial factor and the reinforcement ratio are dimensionless.
            r"c_{v1}": f"{self.c_v1:.{n}f}",
            r"f_{ck}": rf"{self.f_ck:.{n}f} \ MPa",
            r"\gamma_C": f"{self.gamma_c:.{n}f}",
            r"\mu_v": f"{self.mu_v:.{n}f}",
            r"\sigma_n": rf"{self.sigma_n:.{n}f} \ MPa",
            r"f_{cd}": rf"{self.f_cd:.{n}f} \ MPa",
            r"\rho_i": f"{self.rho_i:.{n}f}",
            r"f_{yd}": rf"{self.f_yd:.{n}f} \ MPa",
            r"\alpha": rf"{self.alpha:.{n}f} \ deg",
        },
        unique_symbol_check=False,
    )
    return LatexFormula(
        return_symbol=r"\tau_{Rdi}",
        result=f"{self:.{n}f}",
        equation=_equation,
        numeric_equation=_numeric_equation,
        numeric_equation_with_units=_numeric_equation_with_units,
        comparison_operator_label="=",