formula_8_70
codes.eurocode.fpr_en_1992_1_1_2023.chapter_8_ultimate_limit_states.formula_8_70
Formula 8.70 from FprEN 1992-1-1:2023: Chapter 8 - Ultimate Limit State.
Classes:
-
Form8Dot70CheckPreventCrushingOfCompressionFieldInFlange–Class representing formula 8.70 for the check that prevents crushing of the compression field in the flange.
codes.eurocode.fpr_en_1992_1_1_2023.chapter_8_ultimate_limit_states.formula_8_70.Form8Dot70CheckPreventCrushingOfCompressionFieldInFlange
Form8Dot70CheckPreventCrushingOfCompressionFieldInFlange(
tau_ed: MPA, theta_f: DEG, nu: DIMENSIONLESS, f_cd: MPA
)
Bases: ComparisonFormula
Class representing formula 8.70 for the check that prevents crushing of the compression field in the flange.
The check compares the compressive stress in the compression field [\(\sigma_{cd}\)] with the compressive strength available to it [\(\nu \cdot f_{cd}\)]. It evaluates to True when the stress does not exceed that strength, which means the compression field in the flange does not crush; False means that crushing is not prevented and that the flange fails this verification.
The standard writes the compressive stress and the condition it has to satisfy on one line. The line is a
verification and not a value with a cap on it, since the paragraph introduces it with "the following
condition should be satisfied", so it is implemented as a comparison. The stress itself remains available
through the lhs property.
Check whether the compression field in the flange is safe from crushing.
FprEN 1992-1-1:2023 (E) art. 8.2.5(4) - Formula (8.70)
Parameters:
-
tau_ed(MPA) –[\(\tau_{Ed}\)] Longitudinal shear stress at the junction between one side of a flange and the web according to Formula (8.65) [\(MPa\)].
-
theta_f(DEG) –[\(\theta_f\)] Selected inclination of the compression field in the flange with respect to the longitudinal axis, bounded by Formulas (8.67) and (8.68). The printed formula also contains [\(\tan\theta_f\)], which is taken as the reciprocal of [\(\cot\theta_f\)] [\(degrees\)].
-
nu(DIMENSIONLESS) –[\(\nu\)] Strength reduction factor, for which 0,5 may be used according to Formula (8.71) [\(-\)].
-
f_cd(MPA) –[\(f_{cd}\)] Design value of the compressive strength of concrete [\(MPa\)].
Source code in blueprints/codes/eurocode/fpr_en_1992_1_1_2023/chapter_8_ultimate_limit_states/formula_8_70.py
31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 | |
codes.eurocode.fpr_en_1992_1_1_2023.chapter_8_ultimate_limit_states.formula_8_70.Form8Dot70CheckPreventCrushingOfCompressionFieldInFlange.latex
latex(n: int = 3) -> LatexFormula
Returns LatexFormula object for formula 8.70.
Source code in blueprints/codes/eurocode/fpr_en_1992_1_1_2023/chapter_8_ultimate_limit_states/formula_8_70.py
88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 | |