formula_8_60
codes.eurocode.fpr_en_1992_1_1_2023.chapter_8_ultimate_limit_states.formula_8_60
Formula 8.60 from FprEN 1992-1-1:2023: Chapter 8: Ultimate limit states (ULS).
Classes:
-
Form8Dot60CheckCompressionFieldStressInclinedShearReinforcement–Class representing formula 8.60 for the verification of the stress in the compression field of members
codes.eurocode.fpr_en_1992_1_1_2023.chapter_8_ultimate_limit_states.formula_8_60.Form8Dot60CheckCompressionFieldStressInclinedShearReinforcement
Form8Dot60CheckCompressionFieldStressInclinedShearReinforcement(
tau_ed: MPA, theta: DEG, alpha_w: DEG, nu: DIMENSIONLESS, f_cd: MPA
)
Bases: ComparisonFormula
Class representing formula 8.60 for the verification of the stress in the compression field of members with inclined shear reinforcement.
This replaces Formula (8.44) for such members, and it carries the character of that formula: 8.2.3(5) introduces (8.44) with "The stress in the compression field in all cross-sections shall be verified according to", so the relation is a verification that passes or fails and not a value to be clamped. The stress itself remains available as [\(lhs\)], and [\(unity\_check\)] gives the ratio to its limit.
Verify the stress in the compression field against its limit.
FprEN 1992-1-1:2023 (E) art 8.2.3 (13) - Formula (8.60)
Parameters:
-
tau_ed(MPA) –[\(\tau_{Ed}\)] Average shear stress over the cross-section according to Formula (8.18) [\(MPa\)].
-
theta(DEG) –[\(\theta\)] Inclination of the compression field in the web, selected within the range of Formula (8.58), see Form8Dot58CheckCotangentInclinedShearReinforcement [\(degrees\)].
-
alpha_w(DEG) –[\(\alpha_w\)] Inclination of the shear reinforcement, measured positive as shown in Figure 8.11 b). The standard gives this clause for [\(45 \leq \alpha_w < 90\)] degrees, which is a condition of application and is not enforced. Angles above 90 degrees are rejected, since the standard says they should be avoided [\(degrees\)].
-
nu(DIMENSIONLESS) –[\(\nu\)] Strength reduction factor for concrete cracked in shear. A value of 0,5 may be adopted when using the angles of the compression field given in 8.2.3(4), see 8.2.3(6) [\(-\)].
-
f_cd(MPA) –[\(f_{cd}\)] Design value of the compressive strength of concrete [\(MPa\)].
Source code in blueprints/codes/eurocode/fpr_en_1992_1_1_2023/chapter_8_ultimate_limit_states/formula_8_60.py
27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 | |
codes.eurocode.fpr_en_1992_1_1_2023.chapter_8_ultimate_limit_states.formula_8_60.Form8Dot60CheckCompressionFieldStressInclinedShearReinforcement.latex
latex(n: int = 3) -> LatexFormula
Returns LatexFormula object for formula 8.60.
Source code in blueprints/codes/eurocode/fpr_en_1992_1_1_2023/chapter_8_ultimate_limit_states/formula_8_60.py
82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 | |